| Sign In | Join Free | My autochinanet.com |
|
Brand Name : SIEMENS
Model Number : 6ES7515-2AM01-0AB0
Certification : CE
Place of Origin : Germany
MOQ : 1
Price : USD
Payment Terms : L/C, T/T
Supply Ability : 100
Delivery Time : 10-12Days
Packaging Details : 15,10 x 15,40 x 4,60
Number Of Analog Outputs : 16
Cpu Type : S7-1516
Weight : 0.8 kg
Certifications : CE, UL, CSA
Dimensions : 130 x 125 x 120 mm
Number Of Digital Outputs : 32
Number Of Analog Inputs : 16
Programming Languages : Ladder Logic, Function Block Diagram, Structured Text, Graphical, SCL
Memory : 4 MB
Number Of Digital Inputs : 32
Protection Rating : IP20
Communication Interfaces : PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, OPC UA
Operating Temperature Range : -20 to 60 degrees Celsius
Power Supply : 24V DC
SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA
The SIEMENS 6ES7515-2AM01-0AB0 is a central processing unit (CPU) that is part of the SIMATIC S7-1500 automation system. Some key features of this CPU include:
Work Memory: 500 KB for program storage and 3 MB for data storage
This provides ample memory capacity for program code and data processing in automation applications.
CPU Type: The CPU is based on a high-performance processor that can execute program logic and control industrial processes efficiently.
Interfaces: The CPU has integrated interfaces such as PROFINET for communication with other devices on an industrial network.
Scalability: The CPU is part of the modular SIMATIC S7-1500 system, allowing it to be easily integrated into larger automation solutions.
Safety Features: The CPU supports functional safety capabilities for applications that require enhanced protection.
Programming: It can be programmed using the STEP 7 engineering software from Siemens, providing a comprehensive automation programming environment.
| General information | ||
| Product type designation | CPU 1515-2 PN | |
| HW functional status | FS03 | |
| Firmware version | V2.9 | |
| Product function | ||
| ● I&M data | Yes; I&M0 to I&M3 | |
| ● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central) | |
| Engineering with | ||
| ● STEP 7 TIA Portal configurable/integrated from version | V17 (FW V2.9) / V13 (FW V1.5) or higher | |
| Configuration control | ||
| via dataset | Yes | |
| Display | ||
| Screen diagonal [cm] | 6.1 cm | |
| Control elements | ||
| Number of keys | 6 | |
| Mode selector switch | 1 | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes | |
| Mains buffering | ||
| ● Mains/voltage failure stored energy time | 5 ms | |
| Input current | ||
| Current consumption (rated value) | 0.8 A | |
| Inrush current, max. | 2.4 A; Rated value | |
| I²t | 0.02 A²·s | |
| Power | ||
| Infeed power to the backplane bus | 12 W | |
| Power consumption from the backplane bus (balanced) | 6.2 W | |
| Power loss | ||
| Power loss, typ. | 6.3 W | |
| Memory | ||
| Number of slots for SIMATIC memory card | 1 | |
| SIMATIC memory card required | Yes | |
| Work memory | ||
| ● integrated (for program) | 500 kbyte | |
| ● integrated (for data) | 3 Mbyte | |
| Load memory | ||
| ● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte | |
| Backup | ||
| ● maintenance-free | Yes | |
| CPU processing times | ||
| for bit operations, typ. | 30 ns | |
| for word operations, typ. | 36 ns | |
| for fixed point arithmetic, typ. | 48 ns | |
| for floating point arithmetic, typ. | 192 ns | |
| CPU-blocks | ||
| Number of elements (total) | 8 000; Blocks (OB, FB, FC, DB) and UDTs | |
| DB | ||
| ● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
| ● Size, max. | 3 Mbyte; For DBs with absolute addressing, the max. size is 64 KB | |
| FB | ||
| ● Number range | 0 ... 65 535 | |
| ● Size, max. | 500 kbyte | |
| FC | ||
| ● Number range | 0 ... 65 535 | |
| ● Size, max. | 500 kbyte | |
| OB | ||
| ● Size, max. | 500 kbyte | |
| ● Number of free cycle OBs | 100 | |
| ● Number of time alarm OBs | 20 | |
| ● Number of delay alarm OBs | 20 | |
| ● Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 500 µs | |
| ● Number of process alarm OBs | 50 | |
| ● Number of DPV1 alarm OBs | 3 | |
| ● Number of isochronous mode OBs | 2 | |
| ● Number of technology synchronous alarm OBs | 2 | |
| ● Number of startup OBs | 100 | |
| ● Number of asynchronous error OBs | 4 | |
| ● Number of synchronous error OBs | 2 | |
| ● Number of diagnostic alarm OBs | 1 | |
| Nesting depth | ||
| ● per priority class | 24 | |
| Counters, timers and their retentivity | ||
| S7 counter | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC counter | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| S7 times | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC timer | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| Data areas and their retentivity | ||
| Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB | |
| Extended retentive data area (incl. timers, counters, flags), max. | 3 Mbyte; When using PS 6 0W 24/48/60 V DC HF | |
| Flag | ||
| ● Size, max. | 16 kbyte | |
| ● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | |
| Data blocks | ||
| ● Retentivity adjustable | Yes | |
| ● Retentivity preset | No | |
| Local data | ||
| ● per priority class, max. | 64 kbyte; max. 16 KB per block | |
| Address area | ||
| Number of IO modules | 8 192; max. number of modules / submodules | |
| I/O address area | ||
| ● Inputs | 32 kbyte; All inputs are in the process image | |
| ● Outputs | 32 kbyte; All outputs are in the process image | |
| per integrated IO subsystem | ||
| — Inputs (volume) | 8 kbyte | |
| — Outputs (volume) | 8 kbyte | |
| per CM/CP | ||
| — Inputs (volume) | 8 kbyte | |
| — Outputs (volume) | 8 kbyte | |
| Subprocess images | ||
| ● Number of subprocess images, max. | 32 | |
| Hardware configuration | ||
| Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) | |
| Number of DP masters | ||
| ● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
| Number of IO Controllers | ||
| ● integrated | 2 | |
| ● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
| Rack | ||
| ● Modules per rack, max. | 32; CPU + 31 modules | |
| PtP CM | ||
| ● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
| Time of day | ||
| Clock | ||
| ● Type | Hardware clock | |
| ● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
| ● Deviation per day, max. | 10 s; Typ.: 2 s | |
| Operating hours counter | ||
| ● Number | 16 | |
| Clock synchronization | ||
| ● supported | Yes | |
| ● in AS, master | Yes | |
| ● in AS, slave | Yes | |
| ● on Ethernet via NTP | Yes | |
| Interfaces | ||
| Number of PROFINET interfaces | 2 | |
| 1. Interface | ||
| Interface types | ||
| ● RJ 45 (Ethernet) | Yes; X1 | |
| ● Number of ports | 2 | |
| ● integrated switch | Yes | |
| Protocols | ||
| ● IP protocol | Yes; IPv4 | |
| ● PROFINET IO Controller | Yes | |
| ● PROFINET IO Device | Yes | |
| ● SIMATIC communication | Yes | |
| ● Open IE communication | Yes; Optionally also encrypted | |
| ● Web server | Yes | |
| ● Media redundancy | Yes | |
| PROFINET IO Controller | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | Yes | |
| — Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) | |
| — IRT | Yes | |
| — PROFIenergy | Yes; per user program | |
| — Prioritized startup | Yes; Max. 32 PROFINET devices | |
| — Number of connectable IO Devices, max. | 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
| — Of which IO devices with IRT, max. | 64 | |
| — Number of connectable IO Devices for RT, max. | 256 | |
| — of which in line, max. | 256 | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
| — Number of IO Devices per tool, max. | 8 | |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
| Update time for IRT | ||
| — for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive | |
| — for send cycle of 500 µs | 500 µs to 8 ms | |
| — for send cycle of 1 ms | 1 ms to 16 ms | |
| — for send cycle of 2 ms | 2 ms to 32 ms | |
| — for send cycle of 4 ms | 4 ms to 64 ms | |
| — With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) | |
| Update time for RT | ||
| — for send cycle of 250 µs | 250 µs to 128 ms | |
| — for send cycle of 500 µs | 500 µs to 256 ms | |
| — for send cycle of 1 ms | 1 ms to 512 ms | |
| — for send cycle of 2 ms | 2 ms to 512 ms | |
| — for send cycle of 4 ms | 4 ms to 512 ms | |
| PROFINET IO Device | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | No | |
| — IRT | Yes | |
| — PROFIenergy | Yes; per user program | |
| — Shared device | Yes | |
| — Number of IO Controllers with shared device, max. | 4 | |
| — activation/deactivation of I-devices | Yes; per user program | |
| — Asset management record | Yes; per user program | |
| 2. Interface | ||
| Interface types | ||
| ● RJ 45 (Ethernet) | Yes; X2 | |
| ● Number of ports | 1 | |
| ● integrated switch | No | |
| Protocols | ||
| ● IP protocol | Yes; IPv4 | |
| ● PROFINET IO Controller | Yes | |
| ● PROFINET IO Device | Yes | |
| ● SIMATIC communication | Yes | |
| ● Open IE communication | Yes; Optionally also encrypted | |
| ● Web server | Yes | |
| ● Media redundancy | No | |
| PROFINET IO Controller | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | No | |
| — Direct data exchange | No | |
| — IRT | No | |
| — PROFIenergy | Yes; per user program | |
| — Prioritized startup | No | |
| — Number of connectable IO Devices, max. | 32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
| — Number of connectable IO Devices for RT, max. | 32 | |
| — of which in line, max. | 32 | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
| — Number of IO Devices per tool, max. | 8 | |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
| Update time for RT | ||
| — for send cycle of 1 ms | 1 ms to 512 ms | |
| PROFINET IO Device | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | No | |
| — IRT | No | |
| — PROFIenergy | Yes; per user program | |
| — Prioritized startup | No | |
| — Shared device | Yes | |
| — Number of IO Controllers with shared device, max. | 4 | |
| — activation/deactivation of I-devices | Yes; per user program | |
| — Asset management record | Yes; per user program | |
| Interface types | ||
| RJ 45 (Ethernet) | ||
| ● 100 Mbps | Yes | |
| ● Autonegotiation | Yes | |
| ● Autocrossing | Yes | |
| ● Industrial Ethernet status LED | Yes | |
| Protocols | ||
| PROFIsafe | No | |
| Number of connections | ||
| ● Number of connections, max. | 192; via integrated interfaces of the CPU and connected CPs / CMs | |
| ● Number of connections reserved for ES/HMI/web | 10 | |
| ● Number of connections via integrated interfaces | 108 | |
| ● Number of S7 routing paths | 16 | |
| Redundancy mode | ||
| ● H-Sync forwarding | Yes | |
| Media redundancy | ||
| — Media redundancy | only via 1st interface (X1) | |
| — MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client | |
| — MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 | |
| — MRPD | Yes; Requirement: IRT | |
| — Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD | |
| — Number of stations in the ring, max. | 50 | |
| SIMATIC communication | ||
| ● PG/OP communication | Yes; encryption with TLS V1.3 pre-selected | |
| ● S7 routing | Yes | |
| ● S7 communication, as server | Yes | |
| ● S7 communication, as client | Yes | |
| ● User data per job, max. | See online help (S7 communication, user data size) | |
| Open IE communication | ||
| ● TCP/IP | Yes | |
| — Data length, max. | 64 kbyte | |
| — several passive connections per port, supported | Yes | |
| ● ISO-on-TCP (RFC1006) | Yes | |
| — Data length, max. | 64 kbyte | |
| ● UDP | Yes | |
| — Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast | |
| — UDP multicast | Yes; Max. 5 multicast circuits | |
| ● DHCP | Yes | |
| ● DNS | Yes | |
| ● SNMP | Yes | |
| ● DCP | Yes | |
| ● LLDP | Yes | |
| ● Encryption | Yes; Optional | |
| Web server | ||
| ● HTTP | Yes; Standard and user pages | |
| ● HTTPS | Yes; Standard and user pages | |
| OPC UA | ||
| ● Runtime license required | Yes; "Medium" license required | |
| ● OPC UA Client | Yes | |
| — Application authentication | Yes | |
| — Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
| — User authentication | "anonymous" or by user name & password | |
| — Number of connections, max. | 10 | |
| — Number of nodes of the client interfaces, recommended max. | 2 000 | |
| — Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. | 300 | |
| — Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 | |
| — Number of elements for one call of OPC_UA_MethodGetHandleList, max. | 100 | |
| — Number of simultaneous calls of the client instructions for session management, per connection, max. | 1 | |
| — Number of simultaneous calls of the client instructions for data access, per connection, max. | 5 | |
| — Number of registerable nodes, max. | 5 000 | |
| — Number of registerable method calls of OPC_UA_MethodCall, max. | 100 | |
| — Number of inputs/outputs when calling OPC_UA_MethodCall, max. | 20 | |
| ● OPC UA Server | Yes; Data access (read, write, subscribe), method call, custom address space | |
| — Application authentication | Yes | |
| — Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
| — User authentication | "anonymous" or by user name & password | |
| — GDS support (certificate management) | Yes | |
| — Number of sessions, max. | 48 | |
| — Number of accessible variables, max. | 100 000 | |
| — Number of registerable nodes, max. | 20 000 | |
| — Number of subscriptions per session, max. | 20 | |
| — Sampling interval, min. | 100 ms | |
| — Publishing interval, min. | 200 ms | |
| — Number of server methods, max. | 50 | |
| — Number of inputs/outputs per server method, max. | 20 | |
| — Number of monitored items, recommended max. | 2 000; for 1 s sampling interval and 1 s send interval | |
| — Number of server interfaces, max. | 10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace" | |
| — Number of nodes for user-defined server interfaces, max. | 5 000 | |
| ● Alarms and Conditions | Yes | |
| — Number of program alarms | 200 | |
| — Number of alarms for system diagnostics | 100 | |
| Further protocols | ||
| ● MODBUS | Yes; MODBUS TCP | |
| S7 message functions | ||
| Number of login stations for message functions, max. | 64 | |
| Program alarms | Yes | |
| Number of configurable program messages, max. | 10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH | |
| Number of loadable program messages in RUN, max. | 5 000 | |
| Number of simultaneously active program alarms | ||
| ● Number of program alarms | 800 | |
| ● Number of alarms for system diagnostics | 200 | |
| ● Number of alarms for motion technology objects | 160 | |
| Test commissioning functions | ||
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems | |
| Status block | Yes; Up to 8 simultaneously (in total across all ES clients) | |
| Single step | No | |
| Number of breakpoints | 8 | |
| Status/control | ||
| ● Status/control variable | Yes | |
| ● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | |
| ● Number of variables, max. | ||
| — of which status variables, max. | 200; per job | |
| — of which control variables, max. | 200; per job | |
| Forcing | ||

|
|
SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA Images |