Brand Name : SIEMENS
Model Number : 6ES7516-3AN02-0AB0
Certification : CE
Place of Origin : Germany
MOQ : 1
Price : USD
Payment Terms : L/C, T/T
Supply Ability : 100
Delivery Time : 10-12Days
Packaging Details : 15,10 x 15,40 x 4,60
Certifications : CE, UL, CSA, FM, EAC
Number Of Digital Inputs : 16
Integrated Functions : Web server, OPC UA server, security functions
Number Of Analog Inputs : 8
Cpu Type : S7-1510F
Number Of Technology Modules : 8
Operating Temperature : 0-60 degrees Celsius
Memory : 1 MB
Communication Interfaces : PROFINET, PROFIBUS, Ethernet, RS485
Number Of Digital Outputs : 16
Power Supply : 24 V DC
Protection Class : IP20
Number Of Analog Outputs : 8
Programming Languages : Ladder Logic, Function Block Diagram, Structured Control Language
SIEMENS 6ES7516-3AN02-0AB0 PROFIBUS, 10 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED
The SIEMENS 6ES7516-3AN02-0AB0 is a central processing unit (CPU) that is part of the SIMATIC S7-1500 automation system. Here are the key details about this CPU:
PROFIBUS Interface:
- This CPU model is equipped with a PROFIBUS interface, in addition to PROFINET interfaces.
- PROFIBUS is an industrial fieldbus protocol commonly used for connecting automation devices.
- The PROFIBUS interface allows the CPU to communicate with other PROFIBUS-enabled devices on the network.
High-Performance Bit Processing:
- The CPU has an impressive bit performance of 10 nanoseconds per bit operation.
- This extremely fast processing speed enables very responsive and precise control of industrial processes.
SIMATIC Memory Card Required:
- Like the previous model, this CPU requires a SIMATIC memory card to be inserted for operation.
- The memory card provides storage for the user program, configuration data, and other runtime information.
Other Features:
- Work Memory: 1 MB for program and 5 MB for data
- Powerful CPU with high processing capabilities
- PROFINET interfaces with integrated 2-port switch
- Part of the modular SIMATIC S7-1500 system
- Programmed using the STEP 7 engineering software
The combination of the PROFIBUS interface, 10 ns bit performance, and SIMATIC memory card requirement makes this CPU well-suited for demanding industrial automation applications that require high-speed communication and secure data storage.
The key difference between this model (6ES7516-3AN02-0AB0) and the previous model (6ES7516-3AN01-0AB0) is that this model has a different order number, likely indicating a slightly different hardware configuration or feature set, but the core functionality is very similar.
| General information | ||
| Product type designation | CPU 1516-3 PN/DP | |
| HW functional status | FS01 | |
| Firmware version | V2.9 | |
| Product function | ||
| ● I&M data | Yes; I&M0 to I&M3 | |
| ● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central) | |
| Engineering with | ||
| ● STEP 7 TIA Portal configurable/integrated from version | V17 (FW V2.9) / V16 (FW V2.8) or higher; with older TIA Portal versions configurable as 6ES7516-3AN01-0AB0 | |
| Configuration control | ||
| via dataset | Yes | |
| Display | ||
| Screen diagonal [cm] | 6.1 cm | |
| Control elements | ||
| Number of keys | 8 | |
| Mode buttons | 2 | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes | |
| Mains buffering | ||
| ● Mains/voltage failure stored energy time | 5 ms | |
| Input current | ||
| Current consumption (rated value) | 0.85 A | |
| Current consumption, max. | 1.1 A | |
| Inrush current, max. | 2.4 A; Rated value | |
| I²t | 0.02 A²·s | |
| Power | ||
| Infeed power to the backplane bus | 12 W | |
| Power consumption from the backplane bus (balanced) | 6.7 W | |
| Power loss | ||
| Power loss, typ. | 7 W | |
| Memory | ||
| Number of slots for SIMATIC memory card | 1 | |
| SIMATIC memory card required | Yes | |
| Work memory | ||
| ● integrated (for program) | 1 Mbyte | |
| ● integrated (for data) | 5 Mbyte | |
| Load memory | ||
| ● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte | |
| Backup | ||
| ● maintenance-free | Yes | |
| CPU processing times | ||
| for bit operations, typ. | 10 ns | |
| for word operations, typ. | 12 ns | |
| for fixed point arithmetic, typ. | 16 ns | |
| for floating point arithmetic, typ. | 64 ns | |
| CPU-blocks | ||
| Number of elements (total) | 8 000; Blocks (OB, FB, FC, DB) and UDTs | |
| DB | ||
| ● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
| ● Size, max. | 5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB | |
| FB | ||
| ● Number range | 0 ... 65 535 | |
| ● Size, max. | 1 Mbyte | |
| FC | ||
| ● Number range | 0 ... 65 535 | |
| ● Size, max. | 1 Mbyte | |
| OB | ||
| ● Size, max. | 1 Mbyte | |
| ● Number of free cycle OBs | 100 | |
| ● Number of time alarm OBs | 20 | |
| ● Number of delay alarm OBs | 20 | |
| ● Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 250 µs | |
| ● Number of process alarm OBs | 50 | |
| ● Number of DPV1 alarm OBs | 3 | |
| ● Number of isochronous mode OBs | 3 | |
| ● Number of technology synchronous alarm OBs | 2 | |
| ● Number of startup OBs | 100 | |
| ● Number of asynchronous error OBs | 4 | |
| ● Number of synchronous error OBs | 2 | |
| ● Number of diagnostic alarm OBs | 1 | |
| Nesting depth | ||
| ● per priority class | 24 | |
| Counters, timers and their retentivity | ||
| S7 counter | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC counter | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| S7 times | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC timer | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| Data areas and their retentivity | ||
| Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB | |
| Extended retentive data area (incl. timers, counters, flags), max. | 5 Mbyte; When using PS 6 0W 24/48/60 V DC HF | |
| Flag | ||
| ● Size, max. | 16 kbyte | |
| ● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | |
| Data blocks | ||
| ● Retentivity adjustable | Yes | |
| ● Retentivity preset | No | |
| Local data | ||
| ● per priority class, max. | 64 kbyte; max. 16 KB per block | |
| Address area | ||
| Number of IO modules | 8 192; max. number of modules / submodules | |
| I/O address area | ||
| ● Inputs | 32 kbyte; All inputs are in the process image | |
| ● Outputs | 32 kbyte; All outputs are in the process image | |
| per integrated IO subsystem | ||
| — Inputs (volume) | 8 kbyte | |
| — Outputs (volume) | 8 kbyte | |
| per CM/CP | ||
| — Inputs (volume) | 8 kbyte | |
| — Outputs (volume) | 8 kbyte | |
| Subprocess images | ||
| ● Number of subprocess images, max. | 32 | |
| Hardware configuration | ||
| Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) | |
| Number of DP masters | ||
| ● integrated | 1 | |
| ● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
| Number of IO Controllers | ||
| ● integrated | 2 | |
| ● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
| Rack | ||
| ● Modules per rack, max. | 32; CPU + 31 modules | |
| PtP CM | ||
| ● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
| Time of day | ||
| Clock | ||
| ● Type | Hardware clock | |
| ● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
| ● Deviation per day, max. | 10 s; Typ.: 2 s | |
| Operating hours counter | ||
| ● Number | 16 | |
| Clock synchronization | ||
| ● supported | Yes | |
| ● to DP, master | Yes | |
| ● in AS, master | Yes | |
| ● in AS, slave | Yes | |
| ● on Ethernet via NTP | Yes | |
| Interfaces | ||
| Number of PROFINET interfaces | 2 | |
| Number of PROFIBUS interfaces | 1 | |
| 1. Interface | ||
| Interface types | ||
| ● RJ 45 (Ethernet) | Yes; X1 | |
| ● Number of ports | 2 | |
| ● integrated switch | Yes | |
| Protocols | ||
| ● IP protocol | Yes; IPv4 | |
| ● PROFINET IO Controller | Yes | |
| ● PROFINET IO Device | Yes | |
| ● SIMATIC communication | Yes | |
| ● Open IE communication | Yes; Optionally also encrypted | |
| ● Web server | Yes | |
| ● Media redundancy | Yes | |
| PROFINET IO Controller | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | Yes | |
| — Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) | |
| — IRT | Yes | |
| — PROFIenergy | Yes; per user program | |
| — Prioritized startup | Yes; Max. 32 PROFINET devices | |
| — Number of connectable IO Devices, max. | 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
| — Of which IO devices with IRT, max. | 64 | |
| — Number of connectable IO Devices for RT, max. | 256 | |
| — of which in line, max. | 256 | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
| — Number of IO Devices per tool, max. | 8 | |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |

|
|